Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 350
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38246007

RESUMO

To comply with 'World Anti-Doping Agency' (WADA) guidelines, doping control laboratories must continuously adjust their analytical procedures. Therefore, sample preparation continues to play a critical step in modern analytical strategies, namely by replacing the tedious, time and solvent consuming commonly employed (e.g. liquid-liquid extraction). The present contribution proposes, for the first time in doping control, bar adsorptive microextraction (BAµE) as an alternative analytical technique for the qualitative determination of six alkyl amine stimulants (AAs; 1,3-dimethylbutylamine, 1,4-dimethylpentylamine, heptaminol, isometheptene, octodrine and tuaminoheptane) in urine matrices followed by derivatization prior to gas chromatography coupled to mass spectrometry, operating in the selected ion monitoring mode acquisition (GC-MS(SIM)). After selecting the most selective coating phase, i.e., a mixed-mode reversed phase/strong anion exchange sorbent (P2), assays performed under optimized experimental conditions [microextraction - BAµE(P2), 1 h (1,000 rpm), pH 11, 10 % NaCl; back-extraction - methanol (150 µL), 30 min, under sonication], allowed remarkable recoveries ranging from 48.7 % (heptaminol, 200 ng/mL) to 83.1 % (1,4-dimethylpentylamine, 200 ng/mL). The validation assessment assays of the proposed methodology showed suitable limits of identification (5.0-35.0 ng/mL), appropriate linear dynamic ranges (5.0-200.0 ng/mL) and good determination coefficients (r2 > 0.9937), as well as excellent selectivity, robustness, accuracy and precision. To check whether the methodology is fit-for-purpose, four previously analysed proficiency urine samples were successfully tested, in which were unequivocally detected and identified some of the target AAs. The present methodology showed to be a remarkable alternative in comparison to other dedicated analytical approaches to screen AAs in urine matrices, since it is cost-effective, user- and eco-friendly, requiring low volume of urine sample (1 mL). The great potential of this analytical technology in doping control lies in a very effective microextraction combined with the minimization of potential interferents, presenting itself as an added value to be applied to other types of substances and complex matrices.


Assuntos
Estimulantes do Sistema Nervoso Central , Doping nos Esportes , Heptaminol , Microextração em Fase Líquida , Solventes , Cromatografia Gasosa-Espectrometria de Massas
4.
Appl Neuropsychol Adult ; 29(4): 839-844, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-32930604

RESUMO

INTRODUCTION: The Cognitive Reserve (CR) describes the brain's ability to actively cope with neurological damage, enabling the maintenance of premorbid cognitive functioning through compensatory processes. The most common way to estimate CR is through formal education, the intelligence quotient (IQ) and participation in cognitive stimulating activities. In the absence of IQ data, the Irregular Word Reading Test (TeLPI) allows you to estimate the premorbid intelligence. OBJECTIVE: The comparison of the TeLPI results between two times of assessment (baseline and re-assessment) with an interval time (IT) of 9 years. To analyze of the stability of their results as a valid dimension for the CR estimation. RESULTS: The TeLPI presented temporal stability of its results between the two evaluation times (IT = 9.07 ± 1.02). The sample, composed by 63 cognitively healthy participants, showed no differences for the estimated Full Scale IQ (t(62) = 0.49, p = .63), for the Estimated Verbal IQ (t(62) = 0.71, p = .48) and for the estimated Performance IQ (t(62) = 0.64, p = .52). Likewise, no differences were found in the number of TeLPI errors at the two assessment times (t(62) = -0.61, p = .54). CONCLUSIONS: Considering that CR is characterized as being relatively stable, the TeLPI should be included in its assessment, as an indicator with proved stability over a long period of time, on the physiological aging spectrum.


Assuntos
Reserva Cognitiva , Leitura , Seguimentos , Humanos , Inteligência/fisiologia , Testes de Inteligência
5.
Arq. bras. med. vet. zootec. (Online) ; 72(5): 1959-1964, Sept.-Oct. 2020. tab
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1131525

RESUMO

This study aimed to estimate genetic parameters for simulated data of body weight (BW), abdominal width (AW), abdominal length (AL), and oviposition. Simulation was performed based on real data collected at apiaries in the region of Campo das Vertentes, Minas Gerais, Brazil. Genetic evaluations were performed using single- and two-trait models and (co)variance components were estimated by the restricted maximum likelihood method. The heritability for BW, AW, AL and oviposition were 0.54, 0.47, 0.31 and 0.66, respectively. Positive genetic correlations of high magnitude were obtained between BW and AW (0.80), BW and oviposition (0.69), AW and oviposition (0.82), and AL and oviposition (0.96). The genetic correlations between BW and AL (0.11) and between AW and AL (0.26) were considered moderate and low. In contrast, the phenotypic correlations were positive and high between BW and AW (0.97), BW and AL (0.96), and AW and AL (0.98). Phenotypic correlations of low magnitude and close to zero were obtained for oviposition with AL (0.02), AW (-0.02), and BW (-0.03). New studies involving these characteristics should be conducted on populations with biological data in order to evaluate the impact of selection on traits of economic interest.(AU)


Objetivou-se estimar parâmetros genéticos para dados simulados de peso corporal (PC), largura abdominal (LA), comprimento abdominal (CA) e oviposição (OV). A simulação foi conduzida com base em dados reais, coletados em apiários da região do Campo das Vertentes, Minas Gerais. As estimativas das análises genéticas foram realizadas por modelos uni e bicaracterísticos, sendo os componentes de (co) variância estimados pelo método da máxima verossimilhança restrita. As herdabilidades para PC, LA, CA e OV foram de 0,54, 0,47, 0,31 e 0,66 respectivamente. As correlações genéticas foram positivas e de alta magnitude para PC e LA (0,80), PC e OV (0,69), LA e OV (0,82) e CA e OV (0,96). Para PC e CA (0,11) e LA e CA (0,26), as correlações genéticas foram moderadas e de baixa magnitude. As correlações fenotípicas foram positivas e de alta magnitude para PC e LA (0,97), PC e CA (0,96) e LA e CA (0,98). Para OV e CA (0,02), OV e LA (-0,02) e OV e PC (-0,03), foram encontradas correlações fenotípicas de magnitude baixa e próximas de zero. Novos estudos devem ser realizados em populações com dados biológicos, a fim de se observar o impacto da seleção em características de interesse econômico.(AU)


Assuntos
Animais , Oviposição/genética , Abelhas/genética , Peso Corporal/genética , Pesos e Medidas Corporais/classificação , Hereditariedade , Correlação de Dados
6.
Food Chem ; 333: 127536, 2020 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-32707417

RESUMO

Some halophyte plants are currently used in gourmet cuisine due to their unique organoleptic properties. Moreover, they exhibit excellent nutritional and functional properties, being rich in polyphenolics and vitamins. These compounds are associated to strong antioxidant activity and enhanced health benefits. This work compared the nutritional properties and antioxidant potential of three species (Mesembryanthemum nodiflorum, Suaeda maritima and Sarcocornia fruticosa) collected in saltmarshes from Portugal and Spain with those of cultivated plants. The latter were generally more succulent and had higher contents of minerals than plants obtained from the wild and contained less fibre. All species assayed are a good source of proteins, fibres and minerals. Additionally, they are good sources of carotenoids and vitamins A, C and B6 and showed good antioxidant potential particularly S. maritima. Chromatographic analysis of the phenolic profile revealed that ferulic and caffeic acids as the most relevant phenolic compounds detected in the halophytes tested.


Assuntos
Valor Nutritivo , Plantas Tolerantes a Sal/crescimento & desenvolvimento , Plantas Tolerantes a Sal/metabolismo , Antioxidantes/metabolismo , Chenopodiaceae/crescimento & desenvolvimento , Chenopodiaceae/metabolismo , Fenóis/metabolismo
7.
Molecules ; 25(9)2020 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-32370134

RESUMO

: In the present work we propose, for the first time, bar adsorptive microextraction coated with carbon-based phase mixtures, followed by microliquid desorption and high performance liquid chromatography-diode array detection (BAµE-µLD/HPLC-DAD) analysis, to enhance the performance of the determination of traces of benzotriazoles (BTRs), benzothiazoles (BTs), and benzenesulfonamide derivatives (BSDs) in environmental water matrices. Assessing six carbon-based sorbents (CA1, CN1, B test EUR, SX PLUS, SX 1, and R) with different selectivity properties allowed us to tailor the best phase mixture (R, 12.5%/CN1, 87.5%) that has convenient porosity, texture, and surface chemistry (pHPZC,mix ~6.5) for trace analysis of benzenesulfonamide, 1-hydroxybenzotriazole, 1H-benzotriazole, 5-methyl-1H-benzotriazole, benzothiazole, and 1,3-benzothiazol-2-ol chemicals in aqueous media. Optimized experimental conditions provided average recoveries ranging from 37.9% to 59.2%, appropriate linear dynamic ranges (5.0 to 120.0 µg L-1; r2 ≥ 0.9964), limits of detection between 1.0 and 1.4 µg L-1, and good precisions (relative standard deviation (RSD) ≤ 9.3%). The proposed methodology (BAµE(R, 12.5%/CN1, 87.5%)-µLD/HPLC-DAD) also proved to be a suitable sorption-based static microextraction alternative to monitor traces of BTRs, BTs, and BSDs in rain, waste, tap, and estuarine water samples. From the data obtained, the proposed approach showed that the BAµE technique with the addition of lab-made devices allows users to adapt the technique to use sorbents or mixtures of sorbents with the best selectivity characteristics whenever distinct classes of target analytes occur simultaneously in the same application.


Assuntos
Benzotiazóis/análise , Carbono/química , Monitoramento Ambiental/métodos , Microextração em Fase Sólida , Sulfonamidas/química , Triazóis/análise , Poluentes Químicos da Água/análise , Cromatografia Líquida de Alta Pressão , Monitoramento Ambiental/instrumentação , Sensibilidade e Especificidade , Microextração em Fase Sólida/instrumentação , Microextração em Fase Sólida/métodos
8.
Molecules ; 25(6)2020 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-32235801

RESUMO

We developed, optimized and validated a fast analytical cycle using high throughput bar adsorptive microextraction and microliquid desorption (HT-BAµE-µLD) for the extraction and desorption of ketamine and norketamine in up to 100 urine samples simultaneously, resulting in an assay time of only 0.45 min/sample. The identification and quantification were carried out using large volume injection-gas chromatography-mass spectrometry operating in the selected ion monitoring mode (LVI-GC-MS(SIM)). Several parameters that could influencing HT-BAµE were assayed and optimized in order to maximize the recovery yields of ketamine and norketamine from aqueous media. These included sorbent selectivity, desorption solvent and time, as well as shaking rate, microextraction time, matrix pH, ionic strength and polarity. Under optimized experimental conditions, suitable sensitivity (1.0 µg L-1), accuracy (85.5-112.1%), precision (≤15%) and recovery yields (84.9-105.0%) were achieved. Compared to existing methods, the herein described analytical cycle is much faster, environmentally friendly and cost-effective for the quantification of ketamine and norketamine in urine samples. To our knowledge, this is the first work that employs a high throughput based microextraction approach for the simultaneous extraction and subsequent desorption of ketamine and norketamine in up to 100 urine samples simultaneously.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas/instrumentação , Ketamina/análogos & derivados , Ketamina/urina , Microextração em Fase Líquida/métodos , Microextração em Fase Sólida/métodos , Urina/química , Adsorção , Cromatografia Gasosa-Espectrometria de Massas/métodos , Humanos , Ketamina/análise , Ketamina/química , Limite de Detecção , Reprodutibilidade dos Testes , Solventes/química , Água/química
9.
Arq. bras. med. vet. zootec. (Online) ; 72(2): 339-345, Mar./Apr. 2020. ilus
Artigo em Português | LILACS, VETINDEX | ID: biblio-1128182

RESUMO

Objetivou-se descrever os achados clínicos, histopatológicos e moleculares associados à MDC em um cão da raça Pastor-Suiço. O cão possuía uma paraparesia progressiva em membros pélvicos e foi submetido a avaliações clínicas, pelas quais se obteve, entre outros diferenciais, o diagnóstico presuntivo de MDC. Com a evolução dos sinais, o tutor optou pela eutanásia. Os achados histopatológicos da medula espinhal foram compatíveis com uma degeneração segmentar axonal e mielínica. O diagnóstico molecular foi realizado por meio da extração do DNA obtido por swab oral. Uma PCR foi otimizada utilizando-se primers descritos em literatura para amplificar a região do gene SOD1. A amostra foi, então, submetida a sequenciamento unidirecional, que revelou que o animal em questão era homozigoto para o alelo A para a mutação c.118G>A no éxon 2 do gene SOD1. O diagnóstico clínico presuntivo da MDC no presente caso foi esclarecido por meio dos achados histopatológicos, associados aos achados clínicos, e da sua caracterização molecular. Ressalta-se a contribuição deste relato, que traz aspectos clínicos, histopatológicos e moleculares associados à MDC na raça Pastor-Suíço, para a qual, até o presente momento, na literatura consultada, não há relato dessa enfermidade.(AU)


The objective of this study was to describe the clinical, histopathological and molecular findings associated with MDC in a Swiss Shepherd dog. The dog had a progressive paraparesis in pelvic limbs and was submitted to clinical evaluations where, among other differentials, the presumptive diagnosis of MDC was obtained. With the progression of the nervous deficits tutor opted for euthanasia. The histopathological findings of the spinal cord were compatible with axonal and myelinic segmental degeneration. Molecular diagnosis was performed by extracting the DNA obtained by oral swab. PCR was optimized using primers described in the literature to amplify the SOD1 gene region. The sample was then subjected to one-way sequencing which revealed that the animal in question was homozygous for the A allele for the c.118G>A mutation in exon 2 of the SOD1 gene. The presumptive diagnosis of MDC in the present case was clarified by histopathological findings, as well as by its molecular characterization. The contribution of this report brings clinical, histopathological and molecular aspects associated with canine degenerative myelopathy in the Swiss Shepherd breed, that until this moment, in the literature consulted, there is no report of this disease in the breed mentioned.(AU)


Assuntos
Animais , Feminino , Cães , Doenças da Medula Espinal/patologia , Doenças da Medula Espinal/veterinária , Doenças Neurodegenerativas/veterinária , Superóxido Dismutase-1 , Esclerose Amiotrófica Lateral/veterinária , Reação em Cadeia da Polimerase
10.
J Chromatogr A ; 1615: 460750, 2020 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-31866132

RESUMO

A simple, effective, convenient and environmentally friendly methodology using high throughput bar adsorptive microextraction (HT-BAµE) with microliquid desorption in combination with large volume injection-gas chromatography-mass spectrometry operating in the selected-ion monitoring acquisition mode (LVI-GC-MS(SIM)) was applied for the determination of nicotine and cotinine in urine samples. Under optimized experimental conditions, the developed methodology allowed for linear dynamic ranges between 20.0 and 2000.0 µg L-1 with determination coefficients of 0.9991 and 0.9992, as well as average recovery yields of 61.7-67.5% and 53.9-57.8% for nicotine and cotine, respectively. The developed methodology was applied to monitor urine samples from 86 volunteers having different smoking habits, where nicotine and cotinine were quantified in the range from 23.6 to 2612.6 µg L-1. The target compounds were extracted in a HT-BAµE apparatus, which allows for simultaneous microextraction and subsequent back-extraction of up to 100 samples. This is a major improvement over other microextraction techniques. The data from the proposed methodology were satisfactory and in line with current green analytical chemistry guidelines, and proved to be an effective sample preparation alternative with substantial potential for high throughput bioanalysis.


Assuntos
Cotinina/análise , Microextração em Fase Líquida , Nicotina/análise , Urinálise/métodos , Adsorção , Cotinina/isolamento & purificação , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Nicotina/isolamento & purificação
11.
Cell Immunol ; 341: 103928, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31178059

RESUMO

Asthma is a chronic disease with impacts on public health. It affects the airways causing pulmonary inflammation mediated by CD4 T cells type Th2, eosinophilia, mucus hypersecretion, and elevated IgE. The unbalance between cytokines and transcription factors is an important feature in asthma. Probiotics has gaining highlight as a therapy for chronic diseases. Thus, we investigate the Lactobacillus bulgaricus (Lb) effect in murine allergic asthma. BALB/c-mice were sensitized to ovalbumin (OA) on days 0 and 7 and were challenged from day 14-28 with OA. Mice received Lb seven days prior to sensitization and it was kept until day 28. The Lb attenuated the eosinophils infiltration, mucus and collagen secretion, IgE production, pro-inflammatory cytokines, TLR4 expression, GATA3, STAT6 and RORγt in lung. Otherwise, Lb increased the anti-inflammatory cytokines, the T-bet and foxp3. Finally, Lb attenuated the allergic asthma-induced inflammation and airway remodeling by interfering on Th1/Th2 cytokines and STAT6/T-bet transcription factors.


Assuntos
Remodelação das Vias Aéreas/efeitos dos fármacos , Asma/prevenção & controle , Lactobacillus delbrueckii/imunologia , Pneumonia/prevenção & controle , Probióticos/farmacologia , Fator de Transcrição STAT6/imunologia , Proteínas com Domínio T/imunologia , Remodelação das Vias Aéreas/imunologia , Animais , Asma/induzido quimicamente , Asma/imunologia , Asma/microbiologia , Citocinas/genética , Citocinas/imunologia , Modelos Animais de Doenças , Eosinófilos/efeitos dos fármacos , Eosinófilos/imunologia , Eosinófilos/patologia , Fator de Transcrição GATA3/genética , Fator de Transcrição GATA3/imunologia , Regulação da Expressão Gênica , Imunoglobulina E/genética , Imunoglobulina E/imunologia , Masculino , Camundongos , Camundongos Endogâmicos BALB C , Membro 3 do Grupo F da Subfamília 1 de Receptores Nucleares/genética , Membro 3 do Grupo F da Subfamília 1 de Receptores Nucleares/imunologia , Ovalbumina/administração & dosagem , Pneumonia/induzido quimicamente , Pneumonia/imunologia , Pneumonia/microbiologia , Fator de Transcrição STAT6/genética , Transdução de Sinais , Proteínas com Domínio T/genética , Células Th1/efeitos dos fármacos , Células Th1/imunologia , Células Th1/patologia , Equilíbrio Th1-Th2/efeitos dos fármacos , Células Th2/efeitos dos fármacos , Células Th2/imunologia , Células Th2/patologia , Receptor 4 Toll-Like/genética , Receptor 4 Toll-Like/imunologia
12.
Talanta ; 199: 195-202, 2019 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-30952246

RESUMO

In this work, we propose an innovative high throughput (HT) apparatus using the bar adsorptive microextraction (BAµE) technique, which enables the simultaneous enrichment of up to 100 samples. This novel configuration was combined with microliquid desorption and high-performance liquid chromatography-diode array detection to monitor trace levels of eight benzodiazepines (diazepam, prazepam, bromazepam, oxazepam, lorazepam, alprazolam, temazepam and loflazepate) in biological samples. The proposed methodology was fully developed, optimized and validated, resulting in suitable intraday and interday precision (RSD ≤ 15%), with recovery yields ranging from 33.0% to 104.5%. The lower limits of quantification were between 20.0 and 100.0 µg L-1, using 1.0 mL of urine and 0.5 mL of plasma or serum samples. The application of the proposed methodology to real matrices resulted in average sample preparation time of around 2 min per sample, demonstrating that it is user-friendly, cost-effective and a rapid decision-making tool, whenever large number of samples are involved.


Assuntos
Benzodiazepinas/sangue , Benzodiazepinas/urina , Ensaios de Triagem em Larga Escala/economia , Microextração em Fase Líquida/economia , Adsorção , Cromatografia Líquida de Alta Pressão/instrumentação , Ensaios de Triagem em Larga Escala/instrumentação , Humanos , Microextração em Fase Líquida/instrumentação
13.
J Chromatogr A ; 1600: 17-22, 2019 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-31005293

RESUMO

Bar adsorptive microextraction devices were modified with multi-walled carbon nanotubes for the first time. A bar adsorptive microextraction method followed by microliquid desorption and high-performance liquid chromatography with diode array detection was developed for the determination of trace levels of ketoprofen, diclofenac, gemfibrozil and mefenamic acid in water samples. The mean parameters affecting the bar adsorptive microextraction and microliquid desorption efficiency were studied and optimized using a univariate optimization strategy. The methodology was validated in terms of linearity, limits of detection and quantification, recovery, intra- and inter-day precision, accuracy, and matrix effect. The developed method showed lower limits of quantification of 0.35 µg L-1, calibration curves from 0.35 up to 1000.0 µg L-1 and determination coefficients higher than 0.9917. Recoveries in tap, surface, sea and waste water samples at three spiking levels were between 70.2 and 117.3% for all the pharmaceuticals. The coefficients of variation values for intra- (n = 6) and inter-day precisions (n = 18) were below 9.7%. The proposed analytical methodology allowed preconcentration factors up to 250 and proved to be cost-effective, easy to operate and environmentally friendly.


Assuntos
Monitoramento Ambiental/métodos , Nanotubos de Carbono/química , Preparações Farmacêuticas/análise , Poluentes Químicos da Água/análise , Água/química , Adsorção , Cromatografia Líquida de Alta Pressão , Limite de Detecção , Reprodutibilidade dos Testes
14.
Arch Soc Esp Oftalmol (Engl Ed) ; 94(2): 75-80, 2019 Feb.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-30502968

RESUMO

BACKGROUND: The marked decrease in LDL-C levels produced by the inhibitors of the plasma proprotein convertase subtilisin/kexin type 9 (iPCSK9) could be associated with an increased risk of cataracts. METHODS: A meta-analysis was performed that included randomised clinical trials controlled with iPCSK9, alone, or in combination with other lipid-lowering drugs, which reported new cases of cataracts, by searching PubMed/Medline, databases of EMBASE and Cochrane Clinical Trials. A fixed-effect model was used, and a meta-regression was carried out evaluating the relationship between intra-treatment LDL-C and the risk of developing cataracts. RESULTS: Five eligible studies of iPCSK9 including 83,492 patients were taken into account for the analysis, and 531 new cases of cataracts in iPCSK9 group vs. 532 in placebo group were diagnosed. The iPCSK9 therapy was not associated with an increased risk of cataracts [OR: 0.96, 95% CI: 0.85-1.08; P=.86, I2: 0%]. Likewise, no significant association was found between on-treatment LDL-C levels, differences between study arms, and new cases of cataracts. CONCLUSION: In this analysis, the use of iPCSK9 was not associated with an increased risk of cataracts.


Assuntos
Anticorpos Monoclonais Humanizados/efeitos adversos , Anticorpos Monoclonais/efeitos adversos , Anticolesterolemiantes/efeitos adversos , Catarata/etiologia , Inibidores de PCSK9 , Inibidores de Proteases/efeitos adversos , Anticorpos Monoclonais/uso terapêutico , Anticorpos Monoclonais Humanizados/uso terapêutico , Anticolesterolemiantes/uso terapêutico , Catarata/epidemiologia , Colesterol/metabolismo , LDL-Colesterol/metabolismo , Ensaios Clínicos Controlados como Assunto , Células Epiteliais/metabolismo , Humanos , Cristalino/metabolismo , Inibidores de Proteases/uso terapêutico , Ensaios Clínicos Controlados Aleatórios como Assunto , Projetos de Pesquisa , Risco
15.
Science ; 361(6405): 894-899, 2018 08 31.
Artigo em Inglês | MEDLINE | ID: mdl-30139911

RESUMO

The yellow fever virus (YFV) epidemic in Brazil is the largest in decades. The recent discovery of YFV in Brazilian Aedes species mosquitos highlights a need to monitor the risk of reestablishment of urban YFV transmission in the Americas. We use a suite of epidemiological, spatial, and genomic approaches to characterize YFV transmission. We show that the age and sex distribution of human cases is characteristic of sylvatic transmission. Analysis of YFV cases combined with genomes generated locally reveals an early phase of sylvatic YFV transmission and spatial expansion toward previously YFV-free areas, followed by a rise in viral spillover to humans in late 2016. Our results establish a framework for monitoring YFV transmission in real time that will contribute to a global strategy to eliminate future YFV epidemics.


Assuntos
Surtos de Doenças/prevenção & controle , Monitoramento Epidemiológico , Genômica/métodos , Febre Amarela/prevenção & controle , Febre Amarela/transmissão , Vírus da Febre Amarela/isolamento & purificação , Aedes/virologia , Fatores Etários , Animais , Brasil/epidemiologia , Surtos de Doenças/estatística & dados numéricos , Evolução Molecular , Humanos , Filogenia , Reação em Cadeia da Polimerase , Risco , Fatores Sexuais , Análise Espaço-Temporal , Febre Amarela/epidemiologia , Febre Amarela/virologia , Vírus da Febre Amarela/classificação , Vírus da Febre Amarela/genética
16.
J Am Soc Hypertens ; 12(9): 637-640, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30042049

RESUMO

Juxtaglomerular cell tumors are rare, generally benign, and they are one of the secondary surgically treatable causes of arterial hypertension. There are about 100 reported cases on literature, and the diagnosis is usually carried out based on a high clinic suspicion index, mostly in patients with hypokalemia and arterial hypertension. The diagnosis involves blood tests and imaging studies, but it is only definite with histopathological exam after surgical treatment. We present a case of a 22-year-old woman with resistant arterial hypertension and renal and cardiovascular target-organ lesions. High plasmatic renin and a nodular renal mass on magnetic resonance imaging were present. A tumorectomy was performed and the histological exam confirmed a reninoma. After surgery, blood pressure and serum renin values returned to normal without medication. This work focuses on the need to exclude rare secondary causes of hypertension in young patients with resistant forms of this disease.

17.
J Pharmacol Exp Ther ; 367(1): 28-39, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30006476

RESUMO

The inhibition of nicotinic acetylcholine receptors (nAChRs) has been proposed as a potential strategy to develop new antidepressant drugs. This is based on the observation that antidepressants that selectively block noradrenaline (NA) or serotonin (5-HT) reuptake also inhibit nAChRs. Dual antidepressants blocking both NA and 5-HT reuptake were proposed to shorten the delay in exerting their clinical effects; whether duloxetine, a prototype of dual antidepressants, also blocks nAChRs is unknown. Here we explored this question in bovine chromaffin cells (BCCs) that express native α3, α5, and α7 nAChRs and in cell lines expressing human α7, α3ß4, or α4ß2 nAChRs. We have found that duloxetine fully blocked the acetylcholine (ACh)-elicited nicotinic currents in BCCs with an IC50 of 0.86 µM. Such blockade seemed to be noncompetitive, voltage dependent, and partially use dependent. The ACh-elicited membrane depolarization, the elevation of cytosolic calcium ([Ca2+]c), and catecholamine release in BCCs were also blocked by duloxetine. This blockade developed slowly, and the recovery of secretion was also slow and gradual. Duloxetine did not affect Na+ or Ca2+ channel currents neither the high-K+-elicited [Ca2+]c transients and secretion. Of interest was that in cell lines expressing human α7, α3ß4, and α4ß2 nAChRs, duloxetine blocked nicotinic currents with IC50 values of 0.1, 0.56, and 0.85 µM, respectively. Thus, in blocking α7 receptors, which are abundantly expressed in the brain, duloxetine exhibited approximately 10-fold to 100- fold higher potency with respect to reported IC50 values for various antidepressant drugs. This may contribute to the antidepressant effect of duloxetine.


Assuntos
Acetilcolina/farmacologia , Sinalização do Cálcio/efeitos dos fármacos , Células Cromafins/efeitos dos fármacos , Cloridrato de Duloxetina/farmacologia , Fenômenos Eletrofisiológicos/efeitos dos fármacos , Exocitose/efeitos dos fármacos , Receptores Nicotínicos/metabolismo , Antidepressivos/farmacologia , Canais de Cálcio/metabolismo , Catecolaminas/metabolismo , Células Cromafins/citologia , Células Cromafins/metabolismo , Células HEK293 , Humanos , Antagonistas Nicotínicos/farmacologia , Canais de Sódio/metabolismo
18.
Diabetes Metab ; 44(6): 508-513, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-29523487

RESUMO

BACKGROUND: Cholesteryl ester transfer protein (CETP) inhibitors are a class of drugs that targets the CETP enzyme to significantly increase serum high-density lipoprotein cholesterol (HDL-C) and decrease low-density lipoprotein cholesterol (LDL-C) levels. As HDL-C has potential antidiabetic properties, and the beneficial effects of CETP drugs on glucose homoeostasis have not been sufficiently studied, the aims of this study were: (1) to evaluate the effect of CETP inhibitors on the incidence of diabetes; and (2) to assess the association between CETP inhibitor-induced changes in HDL-C levels and incidence of diabetes. METHODS: A meta-analysis was performed of randomized controlled clinical trials of CETP inhibitor therapy, either alone or combined with other lipid-lowering drugs, reporting data from new cases of diabetes with a minimum of 6 months of follow-up, after searching the PubMed/MEDLINE, Embase and Cochrane Controlled Trials databases. A fixed-effects meta-regression model was then applied. RESULTS: Four eligible trials of CETP inhibitors, involving a total of 73,479 patients, were considered for the analyses, including 960 newly diagnosed cases of diabetes in the CTEP inhibitor group vs 1086 in the placebo group. CETP inhibitor therapy was associated with a significant 12% reduction in incidence of diabetes (OR: 0.88, 95% CI: 0.81-0.96; P=0.005). Assessment of the relationship between on-treatment HDL-C and the effect of CETP inhibitors showed a statistically non-significant trend (Z=-1.13, P=0.26). CONCLUSION: CETP inhibitors reduced the incidence of diabetes. The improvement in glucose metabolism may have been related, at least in part, to the increase in HDL-C concentration.


Assuntos
Anticolesterolemiantes/efeitos adversos , Proteínas de Transferência de Ésteres de Colesterol/antagonistas & inibidores , Diabetes Mellitus Tipo 2/epidemiologia , Anticolesterolemiantes/uso terapêutico , HDL-Colesterol/sangue , LDL-Colesterol/sangue , Diabetes Mellitus Tipo 2/sangue , Humanos , Hipercolesterolemia/sangue , Hipercolesterolemia/tratamento farmacológico , Incidência
19.
J Pharm Biomed Anal ; 153: 126-134, 2018 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-29477928

RESUMO

The present contribution aims to design new-generation bar adsorptive microextraction (BAµE) devices that promote an innovative and much better user-friendly analytical approach. The novel BAµE devices were lab-made prepared having smaller dimensions by using flexible nylon-based supports (7.5 × 1.0 mm) coated with convenient sorbents (≈ 0.5 mg). This novel advance allows effective microextraction and back-extraction ('only single liquid desorption step') stages as well as interfacing enhancement with the instrumental systems dedicated for routine analysis. To evaluate the achievements of these improvements, four antidepressant agents (bupropion, citalopram, amitriptyline and trazodone) were used as model compounds in aqueous media combined with liquid chromatography (LC) systems. By using an N-vinylpyrrolidone based-polymer phase good selectivity and efficiency were obtained. Assays performed on 25 mL spiked aqueous samples, yielded average recoveries in between 67.8 ±â€¯12.4% (bupropion) and 88.3 ±â€¯12.1% (citalopram), under optimized experimental conditions. The analytical performance also showed convenient precision (RSD < 12%) and detection limits (50 ng L-1), as well as linear dynamic ranges (160-2000 ng L-1) with suitable determination coefficients (r2 > 0.9820). The application of the proposed analytical approach on biological fluids showed negligible matrix effects by using the standard addition methodology. From the data obtained, the new-generation BAµE devices presented herein provide an innovative and robust analytical cycle, are simple to prepare, cost-effective, user-friendly and compatible with the current LC autosampler systems. Furthermore, the novel devices were designed to be disposable and used together with negligible amounts of organic solvents (100 µL) during back-extraction, in compliance with the green analytical chemistry principles. In short, the new-generation BAµE devices showed to be an eco-user-friendly approach for trace analysis of priority compounds in biological fluids and a versatile alternative over other well-stablished sorption-based microextraction techniques.


Assuntos
Antidepressivos/química , Microextração em Fase Líquida/métodos , Microextração em Fase Sólida/métodos , Adsorção , Cromatografia Líquida de Alta Pressão/métodos , Limite de Detecção , Polímeros/química , Solventes/química , Água/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...